-40%

Parker Balston 4433-05-BQ Filter Tubes - 10 pack (1 box = 10 filters)

$ 66

Availability: 20 in stock
  • All returns accepted: ReturnsNotAccepted
  • Brand: Parker
  • Condition: New

    Description

    You are bidding on 1 box of Parker-Balston Filter Tubes. 1 box = 10 filters.
    Part #:
    4433-05-BQ
    443305BQ
    Brand New.
    Item specifics
    Condition:
    New
    Brand:
    PARKER
    Housing:
    Nylon
    MPN:
    4433-05-BQ
    Max. Flow (CFM):
    6.3
    NumberOfItems:
    1
    Max. Pressure:
    125 psi
    Size:
    Miniature
    Max. Temp. (F):
    230
    Overall Height:
    3.40"
    Max. Flow:
    6.3 cfm
    Overall Width:
    1.10"
    Pipe Size:
    1/4" Tube
    Height (In.):
    3.40
    Bowl Size:
    0.003 oz.
    Max. Pressure (PSI):
    125
    Filter Media:
    Microfibre
    Max. Temp.:
    230 Degrees F
    Bowl Material:
    Nylon
    Housing Material:
    Nylon
    Filter Rating (Microns):
    99.99% at .01
    Width (In.):
    1.10
    Disposable Filter Units for Critical Medical Devices Market Application Publication
    Background:
    Original equipment manufacturers are very concerned with ensuring  efficient removal of undesirable contaminates and producing consistent trouble free operation of their equipment.  In addition, there is a growing trend towards developing and producing smaller, more portable devices that perform similarly to larger predecessor designs.
    Features and benefits:
    •  Completely disposable,  constructed of recyclable plastics
    Disposable Filter Units for Critical Medical Devices Market Application Publication
    Contact Information:
    Parker Hannifin Corporation Filtration and Separation Division 242 Neck Road Haverhill, MA 01835
    phone 800 343 4048 or 978 858 0505 fax 978 478 2501
    www.parker.com/balston
    •  Prevent cross-contamination of samples •  Pressure ratings up to  125 psig •  Temperature to 275°F (135°C)
    Application: One very popular  application for miniature filtration is in oxygen concentrators used to produce high purity oxygen for respiratory patients.  These devices can be large units with castors however the growing trend in this industry is to provide more mobility for the patient and therefore  smaller more portable designs are being developed.  All of these devices require a pump mechanism (small compressor or diaphragm pump) to pull ambient air into the oxygen separation modules.  High efficiency filtration is required to protect the pump from damaging contamination and in some systems filtration is required to protect the patient from contaminates. Requirements for filtration range so widely that specifying a filter is best done on a case by case basis. Parker Balston has a wide range of standard catalog products that have been developed over time to accommodate most typical applications.  In the event standard catalog product is not adaptable to the specific instrument, Parker Balston has the ability to develop product that meets exactly the requirements for
    fit, form and function.  With over 3000 product models and a team of highly experienced design engineers, Parker Balston can provide  a solution to the most demanding  concentrator applications. Case Study: A major medical device manufacturer offers a wide array of oxygen concentrators.  This particular concentrator is designed specifically for offering respiratory patients daily mobility. This concentrator is designed to offer a complete self-contained system that produces a consistent supply of high purity oxygen to patient.  It contains a small pump, oxygen scrubber module and battery power pack.  In addition, two miniature, high efficiency filters are included in the design to protect the pump from damaging contamination. This filtration ensures long term, trouble free operation.  This enables the manufacturer to market this device as a high end, top quality concentrator offering reliable and consistent output of critical oxygen supply. Parker Balston worked closely with this manufacturer in developing a specialized
    disposable filter unit to protect the internal pump from ambient contamination.  Critical design features included quick disconnections, specific length and diameter parameters and high filtration efficiency coupled with long filter life. In a very short period of time prototypes were produced, samples from production runs were tested and approved and now every monitor is shipped with two of these custom disposable filter units. The manufacturer has not only realized trouble free operation (reduced service calls and warranty claims) but also enjoys  significant aftermarket revenue and profits on the resale of the filter units.
    Models 9922-05, 9933-05, 4433-05 and 9900-05 The 99XX-05 models are the smallest Disposable Filter Units with 11.7 ml internal volume.  These models are used in low flow gas or liquid sampling applications, such as liquids to specific-ion analyzers or gases to personal samplers.  The model 9900-05-BK has a color indicating feature, which turns the cartridge red when saturated with oil. The model 4433-05 has 1/4” and 3/8” Barb Connections molded into the inlet/outlet ports. Models 9922-11, 9933-11, and 8800-12 Models 9922-11, 9933-11, and 8800-12 are used for applications similar to the smaller DFUs (Models 9922-05 and 9933-05) which require greater solids holding capacity and can tolerate the increased retention time. Model 8833-11 These Disposable Filter Units are used as continuous coalescing filters with a third port serving as the drain, slip-stream, or by-pass port. Model 9953-11 This model snaps together for easy filter cartridge changeouts. It is designed primarily for low pressure or mild vacuum applications. It is ideal for capturing samples and perform analysis or record weights over time. If used with a X-tube, it is a very effective silencer to compress inlets. Parker Hannifin offers a manual drain valve for removal of coalesced liquids from the Type 8833-11-DX.  Drain Valve:  1/8” NPT (male) x 1/8” ID Tubing.           (Requires elbow part No. 11972).  Part No. 20-125
    Chemical Compatibility Models 9922-05, 9922-11, 8833-11, and 8800-12 Suitable:  Water or steam to 200°F (135°C); concentrated nitric, sulfuric, and hydrochloric acids; chlorine (gas or liquid); sodium hypochlorite, ethylene oxide (gas or liquid); Freons; ammonia (gas, liquid, or aqueous solutions); hydrogen peroxide (all concentrations); bromine (dry and aqueous solutions); all chlorinated solvents except methylene chloride; all aromatic and aliphatic solvents; all alcohols and glycols; aniline; phenol. Limited Use:  Acetone, MEK, dioxane, furfural, methylene chloride. Unsuitable:  Water above 200°F (135°C), THF, DMF, ethylene diamine, chlorosulfonic acid, ethanolamine, pyridine, sulfur trioxide
    Chemical Compatibility Model 9933-11 Suitable:  Water to 158°F (70°C); benzene, toluene, other aromatic hydrocarbons; hydrocarbon solvents and fuels, perchloroethylene; trichloroethylene, nitric acid (to 10%); sulfuric acid (to 40%); hydrochloric acid (to 10%); most salt solutions; sodium and potassium hydroxide (to 50%). Limited Use:  Water at 176°F (80°C); acetone; MEK, acetaldehyde; ammonia (to 25%). Unsuitable:  Water above 158°F (70°C);  alcohols; glycols, phenol; aniline; DMF; concentrated acids; chlorine.
    Model 9922-05 9900-05 4433-05 9933-05 9922-11 9933-11 8833-11 8800-12 9953-11 Inlet and Outlet Ports 1/4” Tubing 1/4” Tubing 1st Tier/Barb 1/4”Tube 1/4” Tubing 1/4” Tubing 1/4” Tubing 1/4” Tubing  1/2” Tubing 0.32” OD    2nd Tier/Barb 3/8”Tube Drain None None None None None None 1/4” Tubing None None Material of Construction PVDF Nylon Nylon Nylon PVDF Nylon Nylon Nylon Polypropylene Filter Cartridge Length 1.25” (3.2 cm) 1.25” (3.2 cm) 1.25” (3.2cm) 1.25” (3.2 cm) 2.25” (5.7 cm) 2.25” (5.7 cm) 2.25” (5.7 cm) 2.25” (5.7 cm) 2.28” (6.35 cm) Maximum Temperature (2) 275°F (135°C) 230°F (110°C) 230°F (110°C) 230°F (110°C) 275°F (135°C) 230°F (110°C) 230°F (110°C) 150°F (66°C) 125°F (52°C) Maximum Pressure (3) 125 psig 125 psig 125 psig 125 psig 125 psig 125 psig 125 psig 50 psi (5) 2 psi Dimensions  1.0”D X 3.25”L 1.0”D X 3.25”L 1.0”D X 3.43”L 1.0”D X 3.25”L 1.4”D X 4.6”L 1.4”D X 4.6”L 1.4”D X 4.6”L 2.24”D X 6.24”L 1.22”D X 3.57”L  (2.5 cm X 8 cm) (2.5 cm X 8 cm) (2.5 cm X 8.72  cm) (2.5 cm X 8  cm) (3.6 cm X 12 cm) (3.6 cm X 12 cm) (3.6 cm X 12 cm) (5.69 cm X 15.85 cm) (3.1 cm X 9.07 cm) Principal Specifications
    DFU Model  Volume of Housing Initial Pressure  Grade Grade Grade Grade Grade  Gallons Liters Drop DQ, DX CQ, CX BQ, BX AQ AAQ 9922-05 0.003 0.01 1 psi 12 10 3 1.5 0.4 4433-05   5 psi 30 25 15 7.3 1.9 9933-05   9922-11 0.0005 0.02 1 psi 18 15 5 2.5 0.6 9933-11   5 psi 45 37 26 12 3.1 8800-12   1 psi 54 44 13 6 1.4    5 psi 129 106 56 26 6.5
    Model  2 psig 20 psig 40 psig 60 psig 80 psig 100 psig 125 psig 9953-11-DX, 8833-11-DX (1) 1.8 3.6 5.8 8.0 10.0 12.0 14.6 9953-11-BX, 8833-11-BX (1) 0.9 1.8 2.9 4.0 5.0 6.0 7.3 9900-05-BK, 4433-05-BX 0.4 0.8 1.3 1.8 2.2 2.7 3.3
    Flow Rates
    Notes: 2  At 0 psig     3  At 110°F (43°C)
    Model 9922-05 9900-05 4433-05 9933-05 9922-11 9933-11 8833-11 8800-12 9953-11 Box of 10 DFUs 9922-05-  (4) 9900-05-  (4) 4433-05-  (4) 9933-05-  (4) 9922-11-  (5) 9933-11-  (5) 8833-11-  (6) 8800-12-  box of 1 (5) 9953-11-  (5)             Available only in Q-grades Box 10 DAU’S (3) 9922-05-  N/A 4433-05-  9933-05-  9922-11-  9933-11-  N/A N/A N/A
    Ordering Information For assistance, call 1-800-343-4048, 8AM to 5PM EST
    Notes: 3  To designate adsorbent in the DAU, insert adsorbent numbers after DAU designation. For example, to obtain a miniature clear nylon DAU with carbon adsorbent, order 9933-05-000. 4  Available only in Q grades. 5  Available in Q or X media. 6  Available only in X media. 7 9953-11 is designed for maximum pressure of 2 psig. 8  Pressure rating in liquid service is 70 PSIG maximum.
    Installation Information
    To pressure pipe or tubing:  Compression fittings for 1/4” O.D. tubing may be obtained from the following manufacturers.  Hoke, Inc. (“Gyrolok”); Crawford Fitting Co. (“Swagelok”); Parker-Hannifin Corp. (“CPI”); Legris, Inc. (push-on fittings); Jaco Mfg. Co. (plastic fittings). The following brass fittings which seal by O-ring compression and which may be completely recovered and reused when changing filters may be purchased from Parker/Balston: Connector: 1/4” tubing to 1/4”  NPT female -  Part No. 11970 (1 per pkg.) Connector: 1/4” tubing to 1/4” tubing -  Part No. 11971 (1 per pkg.) To low pressure plastic tubing:  Tubing with 1/4” ID may be slipped over the DFU and fittings and held with tubing clamps.  Parker Hannifin supplies plastic barbs to connect the DFU to smaller diameter plastic tubing. The connection is suitable for pressures to 50 psig. DFU to 1/16” ID tubing: Part No. 14000 (bag of 20 barbs) DFU to 1/8” ID tubing: Part No. 14001 (bag of 20 barbs)